How do you achieve beautiful quality of light and avoid glare?We light the effect, not the fitting. Luminaires are chosen for their exceptional quality of light and kept discreet or concealed, so the source stays out of view. The result is visual comfort, depth and atmosphere without glaring fixtures.
Do you manage the technical side of the installation?Yes. We handle drivers, control systems and integration with home technology in-house, so the engineering stays behind the scenes. Your designer can recommend a qualified electrician familiar with our fittings, or we can work with your preferred contractor, then commission the scheme to confirm everything performs as designed.
How do you make sure deliveries arrive on time and on budget, without delaying the build?Costs are agreed upfront in your fee proposal and detailed quotation. Orders are then bagged circuit by circuit, room by room, which saves time on site and simplifies installation for your electrician.
Do you supply the fittings as well as design the scheme?Yes. Schemes are built around our own collection of luminaires, drivers and controls, developed in-house and designed in the UK. Your specification and quotation cover every fitting, with the order managed through to delivery, bagged by room and circuit.
CAN MY LIGHTS BE CONTROLLED VIA TABLET OR PHONE?All controls systems offered come with their own SMART phone/tablet standalone applications which allow for more flexibility in controlling the systems. Our controls team will go through how they operate in person and cover all the features that they offer.
DO YOU SELL CONTROL SYSTEMS?Yes we sell lighting controls in house and they are supported by our specialist controls and technical team. We offer controls for various scenarios in the home from Single room solutions to whole home systems. Working alongside respected brands Lutron, Helvar, Rako and Forbes & Lomax we have a solution that will suit your requirements. For any enquiries please contact the customer service centre on 020 7371 9000 or email [email protected]
WHAT IS THE DIFFERENCE BETWEEN CURRENT RATED LEDS AND VOLTAGE RATED LEDS?Current rated LED’s require a constant current such as 350mA or 700mA, these LED products will also require a forward voltage that is specific for the particular LED being used in the product. A current rated LED needs to be specified with these two factors taken into consideration i.e. 4 x LED’s rated at 700mA with a voltage of 3.2vDC each will require a driver that produces 700mA with a minimum voltage of 12.8v. Current LED’s also need to be wired in SERIES. Voltage rated LED’s require a constant voltage such as 24vDC, these LED products will also consume a power (wattage) that is specific f
WHAT IS AN IP RATING?The system is used provide a guide to the degree of protection that a luminaire has against the ingress of solids and liquids. IP Rating: Value Definitions The First Number relates to solids and ranges from 0 to 6. The ratings offer a logical progression from larger to smaller objects, so the lowest number (zero) indicates that there is no protection against touching live parts within the equipment. The most common rating for a light fitting intended for general interior use is IP20, which tells you that nothing larger than 12.5mm diameter can reach a live part when the equipment is fully assemb
WHAT IS THE COLOUR RENDERING INDEX?Colour rendition is the ability of a light source to accurately illuminate a colour compared to a reference source. How is this measured? The current method uses a reference pallet of 8 colours (R1-R8) called the Colour Rendering Index (CRI) developed by the CIE. Latterly an additional 6 (R9-R14) more saturated colours have been added but do not have to be referenced. CRI is stated in terms of a factor of 100 e.g. CRI80 or CRI 90 and is an average of colours tested (Ra). What is the future of Colour Rendition? The Lighting Industry has taken steps to move away from the CRI method as it is too
WHAT DOES THE CORRELATED COLOUR TEMPERATURE MEAN IN REGARDS TO LEDS?Correlated Colour Temperature (CCT) is reference to the colour of light emitted by a reference solid object (Black Body) as it gets hotter from red through to white. It is expressed in degrees Kelvin. The sequence of colours describes a curve within a colour space. This is shown in the diagram on the right. What do John Cullen Lighting Offer? The standard JCL colour offering is 2400K, 2500K (Linear LEDs only), 2700K and 3000K. Why do we offer 2700K? Traditionally residential properties were lit with incandescent lamps which emit light with a colour of roughly 2700K.
WHAT IS COLOUR CONSISTENCY IN TERMS OF LIGHTING?Colour consistency in an index related to the light sources range of variation in chromaticity (colour) that can be picked up by the human eye. Why is this an issue for LED? During the manufacture of LED the colour, luminous flux and forward voltage can all vary. An LED is essentially grown and although accuracy of this has improved over time consistency is still an issue. How is colour difference measured? Colour difference is defined by a steps of MacAdamellipse. The scale is set by ANSI Chromaticity Standard. In short though the smaller the ellipse value (size) the smaller the colour differ
HOW DO LED CHIP MANUFACTURES MANAGE VARIATION?As there is no method today that offers 100% replication of a set specification, so the LED manufacturer measures each LED chip and separates them in separate groups (or bins) which are defined by each manufactures own coding system. In the diagram to the right 8Cis an example bin. At John Cullen Lighting we specify LED chips with the smallest bin possible to allow for consistency among the range.
WHAT IS A LUMEN?Lumens measure how much light you are getting from a bulb. More lumens means it’s a brighter light; fewer lumens means it’s a dimmer light. Lumens let you buy the amount of light you want. So when buying your new bulbs, think lumens, not watts.
WHAT IS THERMAL MANAGEMENT?A common misconception is that LEDs do not generate heat. Although the beam emitted is cool they do, like any other light source, convert electric power in radiant heat. Lifetime of the LED Chip is directly linked to the operating temperature of the LED Chip (often expressed as Tjor Junction Temperature). Poor thermal management where the LED is operating above manufacture guidelines can also lead to colour shift. How does John Cullen manage the operating temperature? There are various methods of doing this, at John Cullen we use the body of the luminaire to draw heat away from the LED chip. W
DO YOU CARRY OUT CONTRACTOR TRAINING?Yes, we run a John Cullen Lighting approved contractor scheme in which contractors attend our customer service centre in Bagley’s Lane London to carry out product training and installation guidelines along with Q&A sessions. Successful contractors are then added to our list of approved contractors that we recommend to clients. For more information contact our customer service centre on 020 7371 9000.